If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-051-24396 | | Well ID: 37-051-24396 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40.049275, -79.636858 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 19: | Line 19: | ||
| Farm/Lease Name: COCHRAN UNIT 23H | | Farm/Lease Name: COCHRAN UNIT 23H | ||
|- | |- | ||
− | | License Status: | + | | License Status: |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
| Permit Date: 2010-10-06 | | Permit Date: 2010-10-06 | ||
+ | |- | ||
+ | | Well Type: GAS | ||
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
|- | |- | ||
| Configuration: Horizontal Well | | Configuration: Horizontal Well | ||
+ | |- | ||
+ | | Conservation: Yes | ||
|- | |- | ||
| Latitude: 40.049275 | | Latitude: 40.049275 | ||
Line 49: | Line 53: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2010-10-06 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2010-12-08 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2011-03-19 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2011-06-29 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2011-08-09 | ||
+ | | Perforation | ||
+ | |- | ||
+ | | 2011-08-09 | ||
+ | | Performed Stimulation | ||
+ | |- | ||
+ | | 2016-04-21 | ||
+ | | DEVIATED | ||
+ | |- | ||
+ | | 2016-04-21 | ||
+ | | NEWLY DRILLED | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
== Fracking Activities == | == Fracking Activities == | ||
==== Fracking Jobs ==== | ==== Fracking Jobs ==== | ||
Line 62: | Line 101: | ||
| 2011-08-17 | | 2011-08-17 | ||
| 2011-08-17 | | 2011-08-17 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 6,317 |
− | | style="text-align: right;" | 3,906,910 | + | | style="text-align: right;" | 3,906,910 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
|- | |- | ||
Line 188: | Line 227: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-06-19 }}</ref> | | accessdate = 2019-06-19 }}</ref> | ||
+ | == Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
+ | |- | ||
+ | | 2011-08-09 | ||
+ | | style="text-align: right;" | | ||
+ | |||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Completion Reports - Stimulations | ||
+ | | publisher = Pennsylvania Department of Conservation and Natural Resources | ||
+ | | date = 2020-03-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-03-02 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 282: | Line 344: | ||
| 2019 | | 2019 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 54,243.00 |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 304 |
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
Line 307: | Line 369: | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Drilling Fluid Waste | + | | Fracing Fluid Waste |
+ | | style="text-align: right;" | 15,032.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
+ | |- | ||
+ | | 2011 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | Drilling Fluid Waste | ||
| style="text-align: right;" | 3,742.49 Bbl | | style="text-align: right;" | 3,742.49 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
Line 314: | Line 383: | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Fracing Fluid Waste | + | | Fracing Fluid Waste |
| style="text-align: right;" | 11,530.00 Bbl | | style="text-align: right;" | 11,530.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 321: | Line 390: | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 550.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | PA0091472 |
|- | |- | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 330.00 Bbl | | style="text-align: right;" | 330.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 335: | Line 404: | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 220.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | PA0095273 |
|- | |- | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Drilling Fluid Waste | + | | Drilling Fluid Waste |
| style="text-align: right;" | 7,858.00 Bbl | | style="text-align: right;" | 7,858.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR123SW001 | | WMGR123SW001 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2012 | | 2012 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Fracing Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 130.00 Bbl |
− | | | + | | CENTRALIZED TREATMENT PLANT FOR RECYCLE |
− | | | + | | WMGR123SW001 |
|- | |- | ||
| 2012 | | 2012 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Fracing Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 5,940.00 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
− | | | + | | |
|- | |- | ||
| 2012 | | 2012 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 15,278.00 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
Line 377: | Line 439: | ||
| 2012 | | 2012 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 135.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR123SW001 | | WMGR123SW001 | ||
Line 384: | Line 446: | ||
| 2012 | | 2012 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,135.00 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
− | | | + | | 34-121-23995 |
|- | |- | ||
| 2013 | | 2013 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 6,987.00 Bbl | | style="text-align: right;" | 6,987.00 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
Line 398: | Line 460: | ||
| 2014 | | 2014 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 2,977.00 Bbl | | style="text-align: right;" | 2,977.00 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
Line 405: | Line 467: | ||
| 2014 | | 2014 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 115.00 Bbl | | style="text-align: right;" | 115.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 412: | Line 474: | ||
| 2015 | | 2015 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 2,587.50 Bbl | | style="text-align: right;" | 2,587.50 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
Line 419: | Line 481: | ||
| 2016 | | 2016 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| style="text-align: right;" | 1,005.55 Bbl | | style="text-align: right;" | 1,005.55 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR123SW019 | | WMGR123SW019 | ||
|- | |- | ||
− | | | + | | 2016 |
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,510.01 Bbl |
− | | REUSE | + | | REUSE OTHER THAN ROAD SPREADING |
| | | | ||
|- | |- | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 290.00 Bbl | | style="text-align: right;" | 290.00 Bbl | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
Line 447: | Line 502: | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid ( | + | | Produced Fluid |
+ | | style="text-align: right;" | 518.50 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2017 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | Produced Fluid | ||
| style="text-align: right;" | 337.50 Bbl | | style="text-align: right;" | 337.50 Bbl | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
Line 454: | Line 516: | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 299.15 Bbl | | style="text-align: right;" | 299.15 Bbl | ||
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
Line 461: | Line 523: | ||
| 2018 | | 2018 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 107.50 Bbl |
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123SW005 |
|- | |- | ||
| 2018 | | 2018 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 55.00 Bbl |
− | | | + | | RESIDUAL WASTE PROCESSING FACILITY |
− | | | + | | WMGR123SW019 |
|- | |- | ||
| 2018 | | 2018 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 502.50 Bbl | | style="text-align: right;" | 502.50 Bbl | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
Line 482: | Line 544: | ||
| 2018 | | 2018 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 470.00 Bbl |
− | | | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
− | | | + | | |
|- | |- | ||
| 2019 | | 2019 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,329.00 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | |
Well ID: 37-051-24396 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.049275,"lon":-79.636858,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Fayette | |
Municipality: Lower Tyrone Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 147974 | |
Farm/Lease Name: COCHRAN UNIT 23H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-10-06 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.049275 | |
Longitude: -79.636858 |
Date | Event |
---|---|
2010-10-06 | New Permit Application |
2010-12-08 | Performed Spud Operation |
2011-03-19 | Drilling Completion |
2011-06-29 | Drilling Completion |
2011-08-09 | Perforation |
2011-08-09 | Performed Stimulation |
2016-04-21 | DEVIATED |
2016-04-21 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-08-17 | 2011-08-17 | 6,317 | 3,906,910 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Proppant (lbs) | Proppant | 100.00 | 10.17 | ||||
Biocide EC 6116A | Nalco | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00683000 | ||
Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | |||||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00114000 | |||||
Scale Inhibitor A | Nalco | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00685000 | ||
Clean Volume (gals) | Carrier/Base Fluid | 100.00 | 89.83 | |||||
GBL | Clearwater International | Gel Breaker | Ethylene glycol | 107-21-1 | 60.00 | 0.00002000 | ||
7.5 Hcl Acid | Used to open perfs | Hydrochloric acid | 7647-01-0 | 7.50 | 0.27 | |||
CMHPG | Ashland | Water Viscosifier | Carboxymethylhydroxyporoyl guar blend | 100.00 | 0.00169000 | |||
Unislik ST 50 | CESI Chemical | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
Iron Control A | Nalco | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00693000 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2011-08-09 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ATLAS RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 380,765.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 217,093.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 146,144.00 | 281 | 0.00 | 0 | 80.00 | 100 |
2015 | CHEVRON APPALACHIA LLC | 133,026.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 106,850.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 83,608.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 62,704.00 | 304 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 54,243.00 | 304 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 15,032.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 3,742.49 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 11,530.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2011 | CHEVRON APPALACHIA LLC | Produced Fluid | 550.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2011 | CHEVRON APPALACHIA LLC | Produced Fluid | 330.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | CHEVRON APPALACHIA LLC | Produced Fluid | 220.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2011 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 7,858.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 130.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 5,940.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHEVRON APPALACHIA LLC | Produced Fluid | 15,278.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHEVRON APPALACHIA LLC | Produced Fluid | 135.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,135.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2013 | CHEVRON APPALACHIA LLC | Produced Fluid | 6,987.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHEVRON APPALACHIA LLC | Produced Fluid | 2,977.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHEVRON APPALACHIA LLC | Produced Fluid | 115.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2015 | CHEVRON APPALACHIA LLC | Produced Fluid | 2,587.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,005.55 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,510.01 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 290.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 518.50 Bbl | REUSE (AT WELL PAD) | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 337.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 299.15 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 107.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 502.50 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 470.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,329.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1947403 | Primary Facility | 2011-02-02 | Routine/Complete Inspection | No Violations Noted | |
1954306 | Primary Facility | 2011-03-03 | Routine/Complete Inspection | No Violations Noted | |
1961149 | Primary Facility | 2011-03-14 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS,E&S AND PITS LOOK GOOD CONDITION. CLEANING HOLE,PREPAIRING TO RUN INTERMEDIATE CASING AND CEMENTING TONIGHT @ 2662'. |
1961155 | Primary Facility | 2011-03-10 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS,E&S AND PITS LOOK GOOD CONDITION.CLEANING HOLE,PREPAIRING TO RUN SURFACE CASING AND CEMENTING TONIGHT @ 560'. |
1961161 | Primary Facility | 2011-03-21 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS.E&S AND PITS LOOK IN GOOD CONDITION.CLEANING HOLE,PREPAIRING TO CEMENT PLUG BACK TO 6010'. MUDDING UP AND CAPPING.WAITING ON ORDERS TO MOVE TO NEXT WELL COCHRAN 22 -H. |
1962345 | Primary Facility | 2011-03-31 | Routine/Complete Inspection | No Violations Noted | |
1968978 | Primary Facility | 2011-04-26 | Complaint Inspection | No Violations Noted | |
1978355 | Primary Facility | 2011-06-06 | Routine/Complete Inspection | No Violations Noted | |
1984562 | Primary Facility | 2011-06-24 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, E&S AND PITS IN GOOD CONDITION.DRILLING @ 10'423' TODAY. |
1984563 | Primary Facility | 2011-06-21 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, E&S AND PITS IN GOOD CONDITION.DRILLING @ 6010' TODAY. |
2004939 | Primary Facility | 2011-07-11 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, E&S & PITS IN GOOD CONDITION. CEMENTING 51/2" PROD. CASING TODAY. |
2099371 | Primary Facility | 2012-09-12 | Routine/Complete Inspection | No Violations Noted | ID sign, E&S PPC Permits in tube, no observable leaks, tanks in containment. |
2139653 | Primary Facility | 2013-02-14 | Routine/Complete Inspection | No Violations Noted | Site ID sign up, permits and plans in tube, site stable, good veg growth, wells labeled. |
2356659 | Primary Facility | 2015-03-31 | Routine/Complete Inspection | No Violations Noted | 2 wells and 2 tanks onsite. Id sign and e&s ok. |
2381786 | Primary Facility | 2015-06-12 | Routine/Complete Inspection | No Violations Noted | On 06/12/15 at approximately 0700 hours I conducted a routine complete inspection of the Cochran Unit. The site was very well vegetated and the wells appeared to be in good condition. The wells were tagged and all required documents were present at the site. |
2561640 | Primary Facility | 2017-02-02 | Routine/Complete Inspection | No Violations Noted |
On 02/02/17 at approximately 0700 hours I conducted a routine complete inspection of the site. The Act 9 sign was in place and all required documents were present at the time of inspection. The site was well vegetated and there were no signs of erosion observed. There were no violations observed at the time of inspection |
2577346 | Primary Facility | 2017-03-31 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2585908 | Primary Facility | 2017-04-24 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2620559 | Primary Facility | 2017-07-17 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2679628 | Primary Facility | 2018-01-03 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was snow covered at the time of inspection. The production equipment appeared to be in good condition and there were no signs of leaks or releases observed. There were no violations observed at the time of inspection. |
2706297 | Primary Facility | 2018-03-06 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2711287 | Primary Facility | 2018-03-28 | Routine/Complete Inspection | No Violations Noted | Well appears properly equipped for production. On site inspection shows no apparent violations. NOVIO |
2734365 | Primary Facility | 2018-05-24 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2824689 | Primary Facility | 2019-01-10 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and tank battery look ok. |
For data sources see[9]