X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-059-26345"

m
m
 
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-059-26345
 
| Well ID: 37-059-26345
| style="height=100%; align=center" rowspan="15" | {{#display_map: 39.794886, -80.054636 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 39.794886, -80.054636 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 19: Line 19:
 
| Farm/Lease Name: PBG-SMITH UNIT 10H
 
| Farm/Lease Name: PBG-SMITH UNIT 10H
 
|-
 
|-
| License Status: Active
+
| License Status:  
 
|-
 
|-
| Spud Date: 2014-08-26
+
| Spud Date:  
 
|-
 
|-
 
| Permit Date: 2013-12-17
 
| Permit Date: 2013-12-17
 +
|-
 +
| Well Type: GAS
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
 
|-
 
|-
 
| Configuration: Horizontal Well
 
| Configuration: Horizontal Well
 +
|-
 +
| Conservation: No
 
|-
 
|-
 
| Latitude: 39.794886
 
| Latitude: 39.794886
Line 49: Line 53:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2013-12-17
 +
| New Permit Application
 +
|-
 +
| 2014-08-26
 +
| Performed Spud Operation
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 
== Fracking Activities ==
 
== Fracking Activities ==
 
==== Fracking Jobs ====
 
==== Fracking Jobs ====
Line 62: Line 83:
 
| 2016-01-13
 
| 2016-01-13
 
| 2016-02-11
 
| 2016-02-11
| style="text-align: right;" | 8436
+
| style="text-align: right;" | 8,436
| style="text-align: right;" | 5,644,880.0
+
| style="text-align: right;" | 5,644,880
 
| style="text-align: right;" |  
 
| style="text-align: right;" |  
 
|-
 
|-
Line 244: Line 265:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-06-19 }}</ref>
 
  | accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 302: Line 334:
 
| 2019
 
| 2019
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 98,564.00
+
| style="text-align: right;" | 367,437.00
| style="text-align: right;" | 90
+
| style="text-align: right;" | 365
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
Line 327: Line 359:
 
| 2014
 
| 2014
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Drill Cuttings (in Tons)
+
| Drill Cuttings
| style="text-align: right;" | 40.26 Tons
+
| style="text-align: right;" | 211.97 Tons
 
| LANDFILL
 
| LANDFILL
| 100592
+
| 100419
 
|-
 
|-
 
| 2014
 
| 2014
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Drilling Fluid Waste (in Barrels)
+
| Drill Cuttings
| style="text-align: right;" | 62.40 Bbl
+
| style="text-align: right;" | 128.09 Tons
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
| LANDFILL
| WMGR123SW001
+
| 100172
 
|-
 
|-
 
| 2014
 
| 2014
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Drill Cuttings (in Tons)
+
| Fracing Fluid Waste
| style="text-align: right;" | 211.97 Tons
+
| style="text-align: right;" | 20.00 Bbl
| LANDFILL
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| 100419
+
| WMGR123SW001
 
|-
 
|-
 
| 2014
 
| 2014
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracing Fluid Waste (in Barrels)
+
| Drilling Fluid Waste
| style="text-align: right;" | 20.00 Bbl
+
| style="text-align: right;" | 62.40 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123SW001
 
| WMGR123SW001
Line 355: Line 387:
 
| 2014
 
| 2014
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Drill Cuttings (in Tons)
+
| Drill Cuttings
| style="text-align: right;" | 128.09 Tons
+
| style="text-align: right;" | 40.26 Tons
 
| LANDFILL
 
| LANDFILL
| 100172
+
| 100592
 +
|-
 +
| 2015
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 208.50 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 
|-
 
|-
 
| 2015
 
| 2015
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Drill Cuttings (in Tons)
+
| Drill Cuttings
 
| style="text-align: right;" | 754.12 Tons
 
| style="text-align: right;" | 754.12 Tons
 
| LANDFILL
 
| LANDFILL
Line 369: Line 408:
 
| 2015
 
| 2015
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Drill Cuttings (in Tons)
+
| Drill Cuttings
 
| style="text-align: right;" | 175.34 Tons
 
| style="text-align: right;" | 175.34 Tons
 
| LANDFILL
 
| LANDFILL
 
| 100172
 
| 100172
|-
 
| 2015
 
| [[CHEVRON APPALACHIA LLC]]
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 208.50 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123SW001
 
 
|-
 
|-
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracturing Fluid Waste (in Barrels) RWC 805
+
| Fracturing Fluid Waste
| style="text-align: right;" | 344.20 Bbl
+
| style="text-align: right;" | 147.82 Tons
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123SW001
 
|-
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| Fracturing Fluid Waste (in Tons) RWC 805
 
| style="text-align: right;" | 21.23 Tons
 
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| 101532
 
| 101532
Line 397: Line 422:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracturing Fluid Waste (in Barrels) RWC 805
+
| Fracturing Fluid Waste
| style="text-align: right;" | 126.59 Bbl
+
| style="text-align: right;" | 8,983.45 Bbl
| RESIDUAL WASTE TRANSFER FACILITY
+
| REUSE OTHER THAN ROAD SPREADING
| 101532
+
|  
 
|-
 
|-
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Synthetic Liner Materials (in Tons) RWC 806
+
| Fracturing Fluid Waste
| style="text-align: right;" | 2.15 Tons
+
| style="text-align: right;" | 24.00 Bbl
| LANDFILL
+
| INJECTION DISPOSAL WELL
| 100663
+
| 34-059-24202
 
|-
 
|-
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracturing Fluid Waste (in Barrels) RWC 805
+
| Produced Fluid
| style="text-align: right;" | 154.51 Bbl
+
| style="text-align: right;" | 3,655.20 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW019
 
| WMGR123SW019
Line 418: Line 443:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracturing Fluid Waste (in Barrels) RWC 805
+
| Drilling Fluid Waste
| style="text-align: right;" | 24.00 Bbl
+
| style="text-align: right;" | 28.50 Bbl
| INJECTION DISPOSAL WELL
 
| 34-059-24202
 
|-
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
 
| style="text-align: right;" | 0.03 Tons
 
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| 101532
 
| 101532
Line 432: Line 450:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Waste Water Treatment Sludge (in Tons) RWC 804
+
| Waste Water Treatment Sludge
 
| style="text-align: right;" | 33.88 Tons
 
| style="text-align: right;" | 33.88 Tons
 
| STORAGE PENDING DISPOSAL OR REUSE
 
| STORAGE PENDING DISPOSAL OR REUSE
Line 439: Line 457:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Fracturing Fluid Waste
| style="text-align: right;" | 3,655.20 Bbl
+
| style="text-align: right;" | 154.51 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW019
 
| WMGR123SW019
Line 446: Line 464:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Drilling Fluid Waste (in Barrels) RWC 803
+
| Fracturing Fluid Waste
| style="text-align: right;" | 28.50 Bbl
+
| style="text-align: right;" | 344.20 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW001
 +
|-
 +
| 2016
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Soil Contaminated by Oil & Gas Related Spills
 +
| style="text-align: right;" | 0.03 Tons
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| 101532
 
| 101532
Line 453: Line 478:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Drilling Fluid Waste (in Barrels) RWC 803
+
| Drilling Fluid Waste
 
| style="text-align: right;" | 62.00 Bbl
 
| style="text-align: right;" | 62.00 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
Line 460: Line 485:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracturing Fluid Waste (in Barrels) RWC 805
+
| Synthetic Liner Materials
| style="text-align: right;" | 71.53 Bbl
+
| style="text-align: right;" | 3.69 Tons
 
| LANDFILL
 
| LANDFILL
 
| 100172
 
| 100172
Line 467: Line 492:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Synthetic Liner Materials (in Tons) RWC 806
+
| Fracturing Fluid Waste
| style="text-align: right;" | 3.69 Tons
+
| style="text-align: right;" | 71.53 Bbl
 
| LANDFILL
 
| LANDFILL
 
| 100172
 
| 100172
Line 474: Line 499:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracturing Fluid Waste (in Barrels) RWC 805
+
| Fracturing Fluid Waste
 
| style="text-align: right;" | 1,094.85 Bbl
 
| style="text-align: right;" | 1,094.85 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
Line 481: Line 506:
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Fracturing Fluid Waste (in Barrels) RWC 805
+
| Drilling Fluid Waste
| style="text-align: right;" | 8,983.45 Bbl
+
| style="text-align: right;" | 110.00 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
|  
+
| WMGR123SW001
 
|-
 
|-
 
| 2016
 
| 2016
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Drilling Fluid Waste (in Barrels) RWC 803
+
| Synthetic Liner Materials
| style="text-align: right;" | 110.00 Bbl
+
| style="text-align: right;" | 2.15 Tons
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
| LANDFILL
 +
| 100663
 +
|-
 +
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 360.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 1,256.69 Bbl
+
| style="text-align: right;" | 57.00 Bbl
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
+
| INJECTION DISPOSAL WELL
|  
+
| 34-119-28776
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 417.69 Bbl
+
| style="text-align: right;" | 6,021.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-059-24202
+
| 34-157-25511
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 6,769.67 Bbl
+
| style="text-align: right;" | 3,203.50 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| REUSE (AT WELL PAD)
| WMGR123SW019
+
|  
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 6,021.00 Bbl
+
| style="text-align: right;" | 417.69 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-157-25511
+
| 34-059-24202
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Soil Contaminated by Oil
| style="text-align: right;" | 59.77 Bbl
+
| style="text-align: right;" | 0.08 Tons
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| 101532
 
| 101532
Line 530: Line 562:
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 57.00 Bbl
+
| style="text-align: right;" | 59.77 Bbl
| INJECTION DISPOSAL WELL
+
| RESIDUAL WASTE TRANSFER FACILITY
| 34-119-28776
+
| 101532
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 3,335.00 Bbl
+
| style="text-align: right;" | 1,256.69 Bbl
| REUSE (AT WELL PAD)
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811
+
| Soil Contaminated by Oil & Gas Related Spills
 
| style="text-align: right;" | 0.08 Tons
 
| style="text-align: right;" | 0.08 Tons
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
Line 551: Line 583:
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 360.00 Bbl
+
| style="text-align: right;" | 44.20 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
| WMGR123SW001
+
| WMGR123SW005
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 44.20 Bbl
+
| style="text-align: right;" | 6,769.67 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 +
|-
 +
| 2018
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 319.50 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW005
 
| WMGR123SW005
Line 565: Line 604:
 
| 2018
 
| 2018
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
 
| style="text-align: right;" | 68.14 Bbl
 
| style="text-align: right;" | 68.14 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
Line 572: Line 611:
 
| 2018
 
| 2018
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 873.50 Bbl
+
| style="text-align: right;" | 5,127.30 Bbl
| REUSE (AT WELL PAD)
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 
| 2018
 
| 2018
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 319.50 Bbl
+
| style="text-align: right;" | 872.50 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| REUSE (AT WELL PAD)
| WMGR123SW005
+
|  
 
|-
 
|-
| 2018
+
| 2019
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 5,127.30 Bbl
+
| style="text-align: right;" | 759.50 Bbl
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
+
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 
| 2019
 
| 2019
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 305.00 Bbl
+
| style="text-align: right;" | 63.00 Bbl
| REUSE (AT WELL PAD)
+
| RESIDUAL WASTE PROCESSING FACILITY
|  
+
| WMGR123SW005
 +
|-
 +
| 2019
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 12.84 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123SW019
 
|-
 
|-
 
| 2019
 
| 2019
 
| [[CHEVRON APPALACHIA LLC]]
 
| [[CHEVRON APPALACHIA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 11.00 Bbl
+
| style="text-align: right;" | 97.00 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  

Latest revision as of 22:20, 14 May 2020

Well Details

Well ID: 37-059-26345
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Dunkard Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 150623
Farm/Lease Name: PBG-SMITH UNIT 10H
License Status:
Spud Date:
Permit Date: 2013-12-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.794886
Longitude: -80.054636

For data sources see[1][2][3]

Well History

Date Event
2013-12-17 New Permit Application
2014-08-26 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2016-01-13 2016-02-11 8,436 5,644,880

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Base Fluid Chevron Carrier/Base Fluid Water (Including Mix Water Supplied by Client) 7732-18-5 100 89.1376 0
J609W Schlumberger Friction Reducer Ammonium Sulfate 7783-20-2 30 0.0052696 0
Urea 57-13-6 5 0.00087827 0
A264 Schlumberger Corrosion Inhibitor Methanol 67-56-1 40 0.00004508 0
Aliphatic acids Proprietary 30 0.00003381 0
Aliphatic alcohols, ethoxylated #1 Proprietary 30 0.00003381 0
Prop-2-yn-1-ol 107-19-7 10 0.00001127 0
B317 Schlumberger Scale Inhibitor Trisodium ortho phosphate 7601-54-9 5 0.00010281 0
Ethane-1,2-diol 107-21-1 5 0.00010281 0
J134 Schlumberger Gel Breaker Hemicellulase enzyme 9012-54-8 100 0.00018934 0
7.5% Acid Schlumberger Perf Cleanup Hydrocloric Acid 7647-01-0 8 0.0100819 0
L058 Schlumberger Iron Stabilizer Sodium erythorbate 6381-77-7 100 0.00053015 0
U042 Schlumberger Iron Chelating Agent Trisodium nitrilotriacetate (im purity) 5064-31-3 10 0.00026755 0
Sodium hydroxide 1310-73-2 5 0.00013378 0
Tetrasodium ethylenediam inetetraacetate 64-02-8 60 0.00160533 0
Proppant Schlumberger Proppant Crystalline Silica 14808-60-7 100 10.7045 0
M300 BASF Corporation Biocide Water 7732-18-5 75 0.0016362 0
Glutaral 111-30-8 25 0.0005454 0
J580 Schlumberger Gelling Agent Carbohydrate Polymer Proprietary 100 0.00662686 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 292,399.00 94 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 815,182.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 485,493.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 367,437.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CHEVRON APPALACHIA LLC Drill Cuttings 211.97 Tons LANDFILL 100419
2014 CHEVRON APPALACHIA LLC Drill Cuttings 128.09 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 20.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Drilling Fluid Waste 62.40 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Drill Cuttings 40.26 Tons LANDFILL 100592
2015 CHEVRON APPALACHIA LLC Drilling Fluid Waste 208.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 CHEVRON APPALACHIA LLC Drill Cuttings 754.12 Tons LANDFILL 100419
2015 CHEVRON APPALACHIA LLC Drill Cuttings 175.34 Tons LANDFILL 100172
2016 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 147.82 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2016 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 8,983.45 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 24.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2016 CHEVRON APPALACHIA LLC Produced Fluid 3,655.20 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Drilling Fluid Waste 28.50 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2016 CHEVRON APPALACHIA LLC Waste Water Treatment Sludge 33.88 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2016 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 154.51 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 344.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2016 CHEVRON APPALACHIA LLC Soil Contaminated by Oil & Gas Related Spills 0.03 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2016 CHEVRON APPALACHIA LLC Drilling Fluid Waste 62.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2016 CHEVRON APPALACHIA LLC Synthetic Liner Materials 3.69 Tons LANDFILL 100172
2016 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 71.53 Bbl LANDFILL 100172
2016 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 1,094.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2016 CHEVRON APPALACHIA LLC Drilling Fluid Waste 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2016 CHEVRON APPALACHIA LLC Synthetic Liner Materials 2.15 Tons LANDFILL 100663
2017 CHEVRON APPALACHIA LLC Produced Fluid 360.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 57.00 Bbl INJECTION DISPOSAL WELL 34-119-28776
2017 CHEVRON APPALACHIA LLC Produced Fluid 6,021.00 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017 CHEVRON APPALACHIA LLC Produced Fluid 3,203.50 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid 417.69 Bbl INJECTION DISPOSAL WELL 34-059-24202
2017 CHEVRON APPALACHIA LLC Soil Contaminated by Oil 0.08 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 CHEVRON APPALACHIA LLC Produced Fluid 59.77 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2017 CHEVRON APPALACHIA LLC Produced Fluid 1,256.69 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Soil Contaminated by Oil & Gas Related Spills 0.08 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 CHEVRON APPALACHIA LLC Produced Fluid 44.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Produced Fluid 6,769.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 319.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 CHEVRON APPALACHIA LLC Produced Fluid 68.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 5,127.30 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 872.50 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 759.50 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 63.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 12.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 CHEVRON APPALACHIA LLC Produced Fluid 97.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2295610 Primary Facility 2014-08-14 Drilling/Alteration No Violations Noted 26" conductor set @ 40' and cemented in
2304829 Primary Facility 2014-09-09 Drilling/Alteration No Violations Noted CONDUCTOR SET. NO RIG ON SITE.
2318376 Primary Facility 2014-10-08 Drilling/Alteration No Violations Noted spud on 10/6/14; drilled to 525'; set 20"csg@ 501'; cemented with returns; drilling @ 913'; Sewickley@ 777-783; Pgh coal@ 897-903; will be running 13 3/8 casing;
2347080 Primary Facility 2015-01-14 Routine/Complete Inspection No Violations Noted Well drilled to TD. Well waiting to be fracked.
2373131 Primary Facility 2015-05-27 Routine/Partial Inspection No Violations Noted
2373892 Primary Facility 2015-04-03 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, Pace drilling on air @ 2428' ( TD ). Running Intermediate Casing and cementing tonight (4/2/2015).
2380234 Primary Facility 2015-06-04 Routine/Complete Inspection No Violations Noted On 06/04/15 at approximately 1100 hours I conducted a routine complete inspection of the PBG Smith site. The Act 9 sign and all required documents were present at the site. The sides of the access road were well vegetated with few bare spots. The site was stabilized. The Nabors Drilling Rig #X07 was on site. There were no violations noted at the time of inspection.
2444449 Primary Facility 2016-01-15 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, Fracing crew starting stimulation of wells.
2453650 Primary Facility 2015-12-31 Routine/Complete Inspection No Violations Noted
2463034 Primary Facility 2016-03-08 Routine/Complete Inspection No Violations Noted On 03/08/16 at approximately 0830 I conducted an incident response inspection of the PBG Smith Unit. On 03/07/16 a spill of approximately 120 barrels of frack fluid occurred. The spill was reported as contained on secondary containment.

The Act 9 sign was in place and all required documents were present in the mailbox. The wells on site are currently being fracked. The containment appeared to be sound and appeared capable of containing the volume of fluid reported as released, due to a high berm on the edge of the containment. There were no signs that any fluid left containment. It is recommended that the area be inspected after containment is removed to verify that no fluid was outside of containment.

2467442 Primary Facility 2016-03-24 Administrative/File Review No Violations Noted

On 03/24/16 at approximately 1050 hours I conducted an administrative inspection in response to a spill at the Chevron PBG Smith well site.

On 01/18/16 at approximately 0930 hours friction reducer was being circulated and a hose became disconnected allowing approximately 130 gallons of friction reducer to be spilled to containment. Operations were immediately shut down to prevent the additional release of fluid. The area was cleaned up in compliance with DEP spill policy.

2479492 Primary Facility 2016-04-14 Incident- Response to Accident or Event No Violations Noted

On 04/14/16 at approximately 0830 hours I conducted an incident response inspection in response to a spill that occurred on 04/13/16. The Act 9 sign was in place and all required documents were present at the site.

On 04/13/16 a spill of 2/3 freshwater and 1/3 reuse water occurred. Approximately 55 barrels were recovered from containment. Chevron discovered that fluid leaked to the ground surface through a bad seam approximately 8” up the containment berm. After the fluid was recovered from the pad surface the faulty seam was repaired. The spill area off containment was excavated and the material placed on a liner and covered to prevent rain infiltration. Confirmatory samples were taken after excavation occurred. The spill volume to the ground was calculated at 30 gallons.

2487777 Primary Facility 2016-05-25 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, Fracing completed ,Rig moving on wells to drill out plugs and run tubing in well.
2507834 Primary Facility 2016-06-06 Routine/Complete Inspection No Violations Noted

On 06/06/16 at approximately 0900 hours I conducted a CEI in response to an NOV issued to Chevron Appalachia LLC for a discharge of approximately 30 gallons of brine fluid that passed through a bad seam in the containment and contacted the ground.

The Act 9 sign was in place and all required documents were present in the mail box. The location of the spill had been excavated, filled, seeded, and mulched. Vegetation had begun to grow in the disturbed area. There were no signs of additional spills or discharges at the time of inspection. There were no violations observed.

2525325 Primary Facility 2016-09-22 Routine/Complete Inspection No Violations Noted On 09/22/16 at approximately 0900 hours I conducted a routine complete inspection of the PBG Smith Unit. The Act 9 sign was in place and all required documents were present at the site. The site was well stabilized and there were no signs of erosion observed at the time of inspection. There were no violations observed at the time of inspection.
2549864 Primary Facility 2016-12-08 Routine/Complete Inspection No Violations Noted On 12/08/16 at approximately 1100 hours I conducted a routine complete inspection of the PBG Smith Unit. The Act 9 sign was in place and all required documents were present at the site. The site was well stabilized and there were no signs of erosion observed at the time of inspection. It appeared that the AST equipment was being removed at the time of inspection. There were no violations observed at the time of inspection.
2567852 Primary Facility 2017-03-06 Routine/Complete Inspection No Violations Noted The Act 9 sign and all required documents were present at the site. The equipment appeared to be in good condition. The site was well vegetated and there were no signs of erosion observed. There were no violations observed at the time of inspection.
2606089 Primary Facility 2017-06-21 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2606091 Primary Facility 2017-06-21 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2608803 Primary Facility 2017-06-21 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2623549 Primary Facility 2017-08-07 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2663905 Primary Facility 2017-11-16 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The AST pad appeared to have been recently restored. Some tire tracks were observed off the access road in the restored area. Aside from the tracks, the restored area and the rest of the site appeared to be well vegetated. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2683506 Primary Facility 2018-01-10 Routine/Complete Inspection No Violations Noted Well appears to be producing. Fencing Co.installing fence around storm water basin.
2738482 Primary Facility 2018-06-04 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required were present at the site. The production equipment appeared to be in good condition. The site overall was well vegetated. Perimeter BMPs had been removed and the area seeded and mulched. A small area off the southwest edge of the pad exhibited thin vegetation. It is recommended the area be seeded and mulched. A minor erosion rill was observed off the southwest edge of the pad in the direction of the basin. It is recommended the area be addressed, seeded, and mulched.
2752517 Primary Facility 2018-07-17 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. A small erosion rill noted in previous inspections had been repaired. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2798628 Primary Facility 2018-10-18 Site Restoration No Violations Noted A site restoration inspection was conducted in response to an NOT submittal from Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and exceeded uniform 70% vegetative cover. There were no signs of erosion observed. PCSM features were installed and appeared to be functioning. The NOT is approved.

For data sources see[8]